Description
Model Number:Zoway-XW12A
1. Compliance:CE Certified
2. Warranty:2 Year limited warranty with lifetime support
3. Delivery Time:In Stock
Email: imani@batterypackassembly.com
Tel:+86 13174506016
WhatsApp:+86 13174506016
WeChat:18659217588
Email: imani@batterypackassembly.com
Feature
1. This tester can analyze polymer and cylindrical batteries from 0.1mA to 12A, up to 5V.
2 The battery tester system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.
Specifications
Items |
Values |
||
Input AC |
AC 220V/110V ±10% / 50Hz |
||
Input power |
851 W |
||
Resolution |
AD:16bit;DA:16bit |
||
Input impendence |
≥1MΩ |
||
Voltage |
CV output range |
25mV~5V |
|
Min discharge voltage |
1.0V for universial holder,1.5V for 2m cable |
||
Accuracy |
± 0.05% of FS |
||
Stability |
± 0.05% of FS |
||
Current |
Output range/channel |
Range1: 5mA-1A; Range2: 1A-12A |
|
Accuracy |
± 0.05% of FS |
||
CV cut-off current |
Range1: 2mA; Range2: 24mA |
||
Stability |
± 0.05% of FS |
||
Power |
Output power/channel |
60 |
W |
Stability |
± 0.1% of FS |
||
Time |
Current rsponse time |
Max rising time:1ms |
|
Working step time |
≤(365*24)h/step Time format-00:00:00.000(h、m、s、ms) |
||
Data record |
Data record conditions |
Min data record interval:100ms |
|
Min voltage change:10mV |
|||
Min current change:Range1: 2mA; Range2: 24mA |
|||
Frequency |
10Hz |
||
Charge |
Charge modes |
CC、CV、CCCV、CP |
|
Cut-off condition |
Voltage、Current、Time、Capacity、-△V |
||
Discharge |
Discharge modes |
CC、CP、CR、CV |
|
Cut-off condition |
Voltage、Current、Time、Capacity、-△V |
||
Pulse |
Charge |
CC、CP |
|
Discharge |
CC、CP |
||
Min pulse width |
500ms |
||
Pulse counts |
Up to 32 |
||
Chg and Dischg switch |
Supported |
||
Cut-off condition |
Voltage、Time |
||
DCIR |
Supported |
||
Cycle |
Max cycles |
65535 |
|
Max steps |
254 |
||
Cycle nest |
3 |
||
Protection |
Safety protection |
● Power-off data protection |
|
● Off-line operation mode |
|||
● User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. |
|||
Channels feature |
Independent pairs of closed loop for constant |
||
Channels control mode |
Independent control |
||
Data acquisition method |
Kelvin connection |
||
Noise |
<85dB |
||
Database |
MySQL |
||
Communicatin |
TCP/IP |
||
Operating system |
Windows 7/8/10 64 bit |
||
Data export |
EXCEL、TXT、CSV、PDF、Plot/Graph |
||
Disk drive |
500GB |
||
Communication port |
Ethernet port |
||
Leak Current |
0.0000005mA |
||
Channels per unit |
8 |
||
Operation and storage environment requirement |
|||
Items |
Values |
||
Operation environment temperature |
0℃~40℃ (When the temperature is 25±10℃, the accuracy error caused by temperature change is less than 50ppm /℃) |
||
Storage environment temperature |
-10℃~50℃ |
||
Operation environment humidity |
≤70% RH(no moisture condensation) |
||
Storage environment humidity |
≤80% RH(no moisture condensation) |
||
Clamps and dimensions |
|||
Items |
Values |
||
Tester pictures |
|
||
Clamps pictures |
|
|
|
Alligator |
Polymer |
Coin |
|
Pictures just for reference |
|||
Dimensions(W*D*H)(mm) |
3U3F,480*730*130 |
Product Images
2018-04-11 17:26:11
2018-04-11 17:26:11
+86-592-3926659
C329l1, Block BC, 1021 Houhai Avenue, Yuyi Community, Shekou Street, Nanshan District, Shenzhen